Clarke 00311C Návod k obsluze Strana 8

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 130
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 7
EN
ENGLISH
Page -8- Form No. 71171A Clarke
®
Operator’s Manual (EN) - Focus Rider
A
B
C
D
E
E, F
Machine Control Panel
On/Off Key Switch (See gure 1, Item D)
The key switch turns “ON” the power to the control panel. “O”
is the “OFF” and “I” is the “ON”.
Brush Up/Down Switch (See gure 1, Item A)
To lower brush head, push the brush switch in the down (+)
position. To lower the brush head to maximum brush pressure,
continue to hold the switch in the down (+) position until the
travel stops. The brush motors will start and solution will ow
(provided the solution is turned “ON”) when the machine begins
to traverse. To raise the brush head, push the brush switch in
the up (-) position until the brush head travel stops or desired
position is reached.
Squeegee Up/Down Switch (See gure 1, Item B)
The squeegee switch is used to raise and lower the squeegee
and to turn on and off the vacuum motor. The vacuum motor
is turned on when the switch is placed in the middle or lower
position. NOTE: When the squeegee switch is placed in the
lower position, the vacuum motor will turn on.
To raise the squeegee, place the switch in either the middle or
up position. The middle position is used for one touch control.
The vacuum motor will stop, after a short delay, when the
switch is placed in the up position.
Hour Meter (See gure 1, Item E)
The hour meter is located on the front display. You must toggle
screens using LCD display button. The hour meter indicates
the number of hours the machine has operated. It displays
brush motor, vacuum motor, traverse motor and total key on
times.
Battery Meter (See gure 1, Item F)
The battery meter indicates the relative charge on the battery
pack. The battery meter is located on screen 1 on the front
display. See page 7.
Solution Flow Control (See gure 1, Item C)
The solution ow switch regulates the ow of chemical solution
to the oor. To increase the ow, toggle (+). To decrease the
ow, toggle (-). To shut off the solution, toggle - until no indica-
tors are visible on display. NOTE: DO NOT run dry!
NOTE: No solution will ow when the machine does not
traverse.
Circuit Breakers
The circuit breaker reset buttons are located on the back side
of the front cover below front display. The breakers are as
follows:
Item A - Main (5 amp)
Item B - Key Switch (5 amp)
Figure 1
Zobrazit stránku 7
1 2 3 4 5 6 7 8 9 10 11 12 13 ... 129 130

Komentáře k této Příručce

Žádné komentáře